Evidence first, with a way out at every stage

We agree what success means before we fit anything, then test against simple methods, first principles and data the model has never seen.

  1. Stage 1

    Audit

    Map your tags, check units and timestamps, and test whether the data can answer the question.

    Gate Is the data fit for use?

  2. Stage 2

    Baseline

    Agree success criteria up front, freeze a test period and score simple methods first.

    Gate Is there room to beat the baseline?

  3. Stage 3

    Model

    Fit the model and test it on data it has never seen, including its misses.

    Gate Does it beat the baseline?

  4. Stage 4

    Shadow run

    Run read-only forecasts alongside operations, with your engineers reviewing each one.

    Gate Is it useful in practice?

  5. Stage 5

    Handover

    Hand over the model, code, documentation and the conditions where it should not be trusted.

    Gate Who owns it from here?

Validated against first principles

Fitting the data isn’t enough. Every data-driven model, surrogate and ROM has to pass these checks before you rely on it.

Conservation
Outputs must close mass and energy balances within an agreed tolerance.
Physical limits
Predictions must respect bounds such as temperatures, compositions and efficiencies that are physically possible.
Correct response
When an input moves, the output has to move the way the physics says it should.
Full-model comparison
Surrogates and ROMs are tested against the first-principles model on runs they never saw.
Known range
Every model records where it was tested, and flags cases outside that range.

Agreed before fitting

Choosing the pass mark after seeing the results would prove nothing, so we set it first.

  • Target assets and operating modes
  • The decision the model supports, and the lead time it needs
  • The existing baseline or operating rule to beat
  • Maximum missed events and false alarms
  • Maximum useful uncertainty
  • Number of independent test events required

Models that say when they don’t know

Outputs carry one of three states, and engineers keep ownership of every decision.

Within validated conditions
The plant is operating in a range the model was tested on.
Review required
Something looks unfamiliar. An engineer should check before relying on it.
Insufficient evidence
The model should not be used for this case.

What you keep

  • A data dictionary and reproducible quality checks
  • The model and its source code
  • A comparison against simple baselines
  • A failure atlas showing where forecasts went wrong
  • A decision note: proceed, narrow the scope or stop

Data handling

NDA first
We sign before any data moves.
Read-only
We never need write access to a control system.
Your data stays yours
Nothing is published or reused without your written agreement.
Engineers decide
Models inform decisions. They don’t act on the plant.

Tell us what you’re hearing at your plant.

Start a project